Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

Holykell Technology Company Limited
  • Audited Supplier
  • 8 yrs

Contact Supplier

Product Highlights

  • Non-Contact Measurement: Clamp-on transducers enable non-fouling operation and easy installation without pipe cutting.
  • Wide Pipe Compatibility: Supports pipe sizes from DN15 to DN6000mm including steel, PVC, and FRP materials.
  • Bi-Directional Flow: Capable of measuring net flow and heat in both forward and reverse directions.
  • Long Data Storage: Automatically records totaliser data for the last 64 days, 64 months, or 5 years.
  • RS485 Communication: Features RS485 interface with MODBUS protocol support for up to 1000m transmission.
  • Flexible Mounting: Supports V-method, W-method, and Z-method mounting based on pipe characteristics.
  • Low Maintenance: No moving parts ensure maintenance-free operation and extended service life.

Product Images of Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485 pictures & photos
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485 pictures & photos
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485 pictures & photos
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485 pictures & photos
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485 pictures & photos
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
  • Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
    Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
  • Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
    Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
  • Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
    Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
  • Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
    Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
  • Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
    Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

Find Similar Products

Product Description

Wholesale price Holykell Ultrasonic clamp on flow meters RS485

Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

Introduction of Wholesale price Holykell Ultrasonic clamp on flow meters RS485

Wholesale price Holykell Ultrasonic clamp on flow meters RS485 is designed to be installed in a fixed location for long-term flow measurement.

 

Ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation.

 

Transit-time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two transducers. The difference in the transit time measured is directly and exactly related to the velocity of the liquid in the pipe.

Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

Specs of Wholesale price Holykell Ultrasonic clamp on flow meters RS485

Products name

Wholesale price Holykell Ultrasonic clamp on flow meters RS485

Main unit

Accuracy

Better than ±1%

Repeatability

Better than 0.2%

Principle

Transit-time measuring principle

Measurement

Period

500ms

Display

LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.

Output

Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.

OCT output: Frequency signal (1~9999HZ)

Relay output: over 20 source signal (no signal, reverse flow etc.)

RS485 serial port

 

Input

Three analogue input

Three-wire PT100 resistor input (optional)

Other functions

Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

pipe

material

Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed

Size

15-6000mm

Straight pipe section

In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)

Liquid

Types

Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid

Temperature

Standard: -30C - 90C ,High-temperature:-30C - 160C

Turbidity

Less than 10000ppm, with a little bubble

 

Flow Direction

Bi-directional measuring, net flow/heat measuring

Environment

Temperature

Main Unit: -30C - 80C

Transducer: -40C -110C, Temperature transducer: select on enquiry

Humidity

Main Unit: 85% RH

Transducer: water-immersible, water depth less than 3m

Cable

Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.

RS-485 interface, transmission distance up to 1000m

Power Supply

AC220V or DC24V

Power Consumption

Less than 1.5W

Protocols

MODBUS, M-BUS, Fuji extended protocol and other factory protocol


Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

You will benifit from our Holykell ultrasonic flow meters as followings:

1.Saving money  

Measuring precision,long lifetime 

2. Low cost

The cost is lower than the other models out there contact us  

3. Less maintenance

No moving parts, maintenance-free

4.Widely used  

Wide range of norminal diameters DN32mm  to DN1000mm  .



Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485


Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485


Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485
Wholesale Price Holykell Ultrasonic Clamp on Flow Meters RS485

Cellphone (wtsapp): +86-18684725345

 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR249649". Items marked "verified" are certified.

Watch Video
Watch Video
Holykell Technology Company Limited
Holykell Technology Company Limited
Holykell Technology Company Limited
Holykell Technology Company Limited
Holykell Technology Company Limited
Holykell Technology Company Limited
Holykell Technology Company Limited
Holykell Technology Company Limited

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 100 Luyun Road, Lugu, Yuelu District, Changsha, Hunan, China
verified Plant Area
490.8 square meters
verified Number of Employees
44
verified Registered Capital
10,100,000 RMB
verified Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, D/P
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port.Shenzhen Port.Guangzhou Port.
verified Supply Chain Partners
20

Our Production Capability & Technical Expertise

verified Main Products
Level Sensor, Flow Meter, Pressure Sensor, Wireless sensors, Temperature sensors
verified Production Lines
4
verified Production Machines
Laser Printing machine, Winding machine, Laser Welding Machine, Electrified high-temperature aging equipment, Constant temperature and humidity detection box, Ultrasonic testing equipment
verified QA/QC inspectors
3 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
8 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2011-01-10
verified Export Year
13 Years
verified Main Markets
North America, Europe, Southeast Asia/ Mideast
verified Repeat Buyers Choice
80%~100%
verified Number of Foreign Trading Staff
21
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE, FCC
verified Cooperated with Fortune 500
Yes

FAQ

What pipe sizes are supported?
It supports pipe sizes ranging from DN15mm to DN6000mm.
Can it measure bidirectional flow?
Yes, it supports bi-directional measuring for both net flow and heat.
What is the data storage capacity?
It can automatically record totaliser data for the last 64 days, 64 months, or 5 years.
What communication protocols are supported?
It supports MODBUS, M-BUS, Fuji extended protocol, and other factory protocols via RS485.
Is the installation non-intrusive?
Yes, the transducers are clamp-on type, allowing for non-contact and non-fouling installation.
What is the power supply requirement?
It accepts AC220V or DC24V power supply with power consumption less than 1.5W.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.